AC / DC sensors for high voltage measurements
CATenergy DC sensor
Informatie
The Mors Smitt CATenergy DC sensor provide an all in one proven, reliable, accurate and cost-effective solution for rolling stock. Based on its full energy measurement function integration with voltage and current measurement and energy calculation according to EN 50463, the CATenergy DC is the perfect compact solution for energy measurement implementation on existing or new build rolling stock.
Functions
- DC Voltage Measurement Function (VMF) according EN 50463
- DC Current Measurement Function (CMF) according EN 50463
- DC Energy Calculation Function (ECF) according EN 50463
Catenary voltage
- From 600 VDC to 3000VDC according EN 50163
Nominal current
- From 900 A to 4000 A dc according EN 50463
- Accurate measurement from 50 ADC (1% error)
Accuracy
- Class 0,5R for DC Voltage Measurement Function according EN 50463
- Class 1R for DC Current Measurement Function according EN 50463
- Class 0,2R for DC Energy Calculation Function according EN 50463
Insulation
- OV4-PD4 according EN 50124-2
- Electrical shock up to 200 kV
- Dielectric 2120 VDC, 1 min
- Dielectric 25 kV, 50 Hz, 1 min for AC catenary fall withstand in case on roof installation
Digital output
- Ethernet 10/100 Mb
- RS 485
IP rate
- IP66 according EN 60529
Fire and Smoke
- R22, HL3 according EN 45545-2
Operating Temperature
- -40 °C to +7 0°C, class TX according EN 50155
Power supply
- Full range from 24 to 110 VDC
Total weight
- From 8 to 12,5 Kg depending on the current range measurement
Dimensions
- 450 * 150 * 100 (length * height * width)
Installation
- Rooftop mounting
- Cabinet mounting
//= _e(SiteTranslations::get('site_product_information_request')) ?>